URM-‘45-‘87-C-CT
Description
RINTChttps://www.reluis.it/en/rintc-dff/ | Type of structure:Residential Building | Construction material:Masonry | Type of Mansory:Lavic stone | Historical/modern:modern | Roof/floor:Reinforced concrete (RC staircase) | Rigid diaphragm:Yes | Design actions:Gravity loads | Design Ag [g]:- | Upgraded according to:- | Site:Catania | Soil Class:C | N. Stories:5 | Regularity in plan:No | Regularity in elevetion:Yes | Building:- | Failure mode:- | Design method:Construction practices | ID-building:URM_‘45-‘87 | ID-building2:C_CT | Performance:GC | Fitting:ML | Intensity Measure:Sa(0.50s) | eta:0.391 | beta:0.426 | Notes:nan
Reference
Iervolino, I., Baraschino, R., & Spillatura, A. (2023). Evolution of Seismic Reliability of Code-Conforming Italian Buildings. Journal of Earthquake Engineering, 27(7), 1740–1768. https://doi.org/10.1080/13632469.2022.2087811
License
This work is licensed under Creative Commons Attribution-NoDerivatives 4.0 International - https://creativecommons.org/licenses/by-nd/4.0/deed.en. See also https://www.reluis.it/en/rintc-dff/
Exposure attributes
Primary hazard: |
Earthquake |
Secondary hazard: |
-- |
Continent: |
Europe |
Country: |
Italy |
Region/City: |
Catania |
building:Direction: |
-- |
building:Material: |
MUR |
building:LLRS: |
LWAL |
building:Height: |
HEX:5 |
building:Year: |
YBET:1945,1987 |
building:Surroundings: |
-- |
building:Occupancy: |
RES |
building:Ground floor hydrodynamics: |
-- |
building:Roof Shape: |
-- |
building:Floor material: |
-- |
building:Foundations: |
-- |
building:Fire protection: |
-- |