Infilled RC frames - low rise - inadequate seismic provisions Europe Sample Data. Buildings: 3 storeys regular infilled frame without seismic design with variation of concrete, steel and infill properties$Paragraph$Seismic Hazard: 3 sets of 10 recorded accelerograms.$Paragraph$Uncertainty both in the material properties and ground motion is considered. Fragility parameters: Medians=[0.0005, 0.0009, 0.003, 0.012, 0.031, 0.052], Standard deviations=[0.0003, 0.0004, 0.0007, 0.003, 0.007, 0.012] Syner-G taxonomy: FRM=MRF FRMM1=None FRMM2=RC NS=3 P=R E=R C=RI CM=FB D=ND FS= FSM= DRS=None RSM= HL=None CL=LC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf

Reference

SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | T. Rossetto & A. Elnashai. A new analytical procedure for the derivation of displacement-based vulnerability curves for populations of RC structures. Engineering Structures 27(3), 397-409, 2005.

License

This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results

Exposure attributes

Primary hazard: Earthquake
Secondary hazard: --
Continent: Europe
Country: --
Region/City: --
building:Direction: --
building:Material: CR
building:LLRS: LFM
building:Height: HBET:1-3
building:Year: --
building:Surroundings: --
building:Occupancy: --
building:Ground floor hydrodynamics: --
building:Roof Shape: --
building:Floor material: --
building:Foundations: --
building:Fire protection: --