TahiriAndMilutinovic-RC-SchoolBuildings
Description
School Buildings Reinforced Concrete - designed on 1983 according to SDC
Kosovo
Sample Data. Buildings: a typical RC structure is selected from several numbers of educational buildings in the region of Gjilian. The building was designed on 1983. The design and construction of educational buildings was done according to SDC.$Paragraph$Seismic Hazard: an earthquake tremor M5.2, h=10 km, I=VII which stroke the city of Gjilian on 24 April 2002 was used.$Paragraph$It is a school building and it is designed and constructed with safety factor of 1.5.$Paragraph$A set of unified fragility curves are obtained with integration of structural and nonstructural components.
Fragility parameters: Medians=[1.02, 1.625, 4.398, 12.271], Standard deviations=[0.379, 0.858, 4.717, 15.97]
Syner-G taxonomy: FRM=MRF
FRMM1=None FRMM2=RC NS=
P= E= C=
CM= D= FS=
FSM= DRS=None RSM=
HL=None CL=LC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf
Reference
SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | F. T.Tahiri, Z.M. Milutinovic, Seismic Risk, vulnerability and retrofit requirements of educational buildings in Kosovo, 14ECEE, Ohrid, 2010.
License
This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results
Exposure attributes
Primary hazard: |
Earthquake |
Secondary hazard: |
-- |
Continent: |
Europe |
Country: |
Kosovo |
Region/City: |
-- |
building:Direction: |
-- |
building:Material: |
CR |
building:LLRS: |
LFM |
building:Height: |
HBET:1-3 |
building:Year: |
-- |
building:Surroundings: |
-- |
building:Occupancy: |
-- |
building:Ground floor hydrodynamics: |
-- |
building:Roof Shape: |
-- |
building:Floor material: |
-- |
building:Foundations: |
-- |
building:Fire protection: |
-- |