TsionisEtAl2011_DualSystem_RC_HR_HC

Description

Dual system building, high rise, designed with high code Euro-Mediterranean Regions Sample Data. Buildings: Some prototype regular buildings $Paragraph$have been analyzed.$Paragraph$$Paragraph$Uncertainty both in the demand and in the capacity have $Paragraph$been considered in the analyses Fragility parameters: Medians=[0.168, 0.401], Standard deviations=[0.085, 0.112] Syner-G taxonomy: FRM=MRF-W FRMM1=None FRMM2=RC NS= P=R E=R C= CM= D= FS= FSM= DRS=None RSM= HL=None CL=HC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf

Reference

SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | Tsionis G., A. Papailia, M.N. Fardis. 2011. Analytical Fragility Functions for Reinforced Concrete Buildings and Buildings Aggregates of Euro-Mediterranean Regions – UPAT methodology. Internal Report, Syner-G Project 2009/2012

License

This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results

Exposure attributes

Primary hazard: Earthquake
Secondary hazard: --
Continent: Europe
Country: --
Region/City: --
building:Direction: --
building:Material: CR
building:LLRS: --
building:Height: HBET:8-19
building:Year: --
building:Surroundings: --
building:Occupancy: --
building:Ground floor hydrodynamics: --
building:Roof Shape: --
building:Floor material: --
building:Foundations: --
building:Fire protection: --