BorziEtAl2008a-RC-8storeys

Description

Reinforced Concrete Buildings - 8 storeys - Non-seismically designed Italy Sample Data. Random population of buildings is generated using Monte Carlo simulation where random variables are used to describe the geometry and the material properties of the structures.$Paragraph$The uncertainty in the geometric and material properties are accounted for in the methodology. Fragility parameters: Medians=[0.23, 0.48, 0.57], Standard deviations=[0.12, 0.27, 0.33] Syner-G taxonomy: FRM=MRF FRMM1=None FRMM2=RC-ASC-HY NS=8 P=IR E=R C=B CM= D=ND FS= FSM= DRS=None RSM= HL=None CL=NC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf

Reference

SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | Borzi B., Pinho R., Crowley H. Simplified pushover-based vulnerability analysis for large-scale assessment of RC buildings. Engineering Structures, 30, 804-820, 2008a

License

This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results

Exposure attributes

Primary hazard: Earthquake
Secondary hazard: --
Continent: Europe
Country: Italy
Region/City: --
building:Direction: --
building:Material: CR
building:LLRS: LFM
building:Height: HEX:8
building:Year: --
building:Surroundings: --
building:Occupancy: --
building:Ground floor hydrodynamics: --
building:Roof Shape: --
building:Floor material: --
building:Foundations: --
building:Fire protection: --