RotaEtAl2008-RMA6-MR-HR
Description
RMA6 - Masonry - regular layout - flexible floors - without tie rods and tie beams - >=3 storey
Italy
Sample Data. Buildings: Damage on masonry and reinforced concrete buildings collected after 1980 Irpinia, 1984 Abruzzo, 1997 Marche, 1998 Pollino and 2002 Marche earthquakes$Paragraph$Seismic Hazard: real earthquakes and Sabetta and Pugliese (1987) GMPE.$Paragraph$The use of real data allows taking into account all the characteristics of the building stock and the ground motion.
Fragility parameters: Medians=[1.77e+19, 1.82e+17, 1153660.0, 2242.171, 32721.9], Standard deviations=[2.116e+43, 6.4379e+34, 598030000000.0, 955889.16, 17220277.9]
Syner-G taxonomy: FRM=BW
FRMM1=None FRMM2=URM NS=
P=R E= C=
CM= D= FS=F
FSM= DRS=None RSM=
HL=None CL=NC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf
Reference
SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | M. Rota, A. Penna, C.L.Strobbia. Processing Italian damage data to derive typological fragility curves. Soil Dynamics and Earthquake Engineering 28(10-11), 933-947, 2008.
License
This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results
Exposure attributes
Primary hazard: |
Earthquake |
Secondary hazard: |
-- |
Continent: |
Europe |
Country: |
Italy |
Region/City: |
-- |
building:Direction: |
-- |
building:Material: |
MUR |
building:LLRS: |
LWAL |
building:Height: |
HBET:3-10 |
building:Year: |
-- |
building:Surroundings: |
-- |
building:Occupancy: |
-- |
building:Ground floor hydrodynamics: |
-- |
building:Roof Shape: |
-- |
building:Floor material: |
-- |
building:Foundations: |
-- |
building:Fire protection: |
-- |