RISK-UE2003-RCMomentFrame-MR-LC-UTCBHybridApproach

Description

Reinforced Concrete Moment Frame - Mid Rise (3-5) - Low Code Europe Fragility parameters: Medians=[0.42, 0.94, 1.549, 4.004], Standard deviations=[0.304, 0.817, 1.595, 4.848] Syner-G taxonomy: FRM=MRF FRMM1=None FRMM2=RC NS= P= E= C= CM= D= FS= FSM= DRS=None RSM= HL=None CL=LC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf

Reference

SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | RISK-UE An Advanced approach to earthquake risk scenarios with applications to different European towns. WP4: Vulnerability of current buildings Risk-UE 2003. UTCB Hybrid Approach

License

This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results

Exposure attributes

Primary hazard: Earthquake
Secondary hazard: --
Continent: Europe
Country: --
Region/City: --
building:Direction: --
building:Material: CR
building:LLRS: LFM
building:Height: HBET:4-7
building:Year: --
building:Surroundings: --
building:Occupancy: --
building:Ground floor hydrodynamics: --
building:Roof Shape: --
building:Floor material: --
building:Foundations: --
building:Fire protection: --