BorziEtAl2008b-MABrick-HighPercentageVoids-3storeys

Description

Brick - High Percentage of Voids - 3 storey Italy Sample Data. Random population of buildings is generated using Monte Carlo simulation where random variables are used to describe the geometry and the material properties of the structures.$Paragraph$The uncertainty in the capacity of the buildings and in the displacement demand is taken into account.$Paragraph$The fragility curves have been generated for In-Plane failure mechanism and for Out-of-Plane failure mechanism. Fragility parameters: Medians=[0.15, 0.19, 0.22, 0.11], Standard deviations=[0.12, 0.13, 0.16, 0.04] Syner-G taxonomy: FRM=BW FRMM1=None FRMM2=URM-FB-H% NS=3 P=R E=R C= CM= D= FS= FSM= DRS=None RSM= HL=None CL=NC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf

Reference

SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | Borzi B., Crowley H., Pinho R. Simplified Pushover-Based Earthquake Loss Assessment (SP-BELA) Method for Masonry Buildings. International Journal of Architectural Heritage, 2:4, 353-376, 2008b.

License

This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results

Exposure attributes

Primary hazard: Earthquake
Secondary hazard: --
Continent: Europe
Country: Italy
Region/City: --
building:Direction: --
building:Material: MUR
building:LLRS: LWAL
building:Height: HEX:3
building:Year: --
building:Surroundings: --
building:Occupancy: --
building:Ground floor hydrodynamics: --
building:Roof Shape: --
building:Floor material: --
building:Foundations: --
building:Fire protection: --