KircilAndPolat2006-RC-5storeys-

variant

Description

RC frame structures-5 storey-1975 Turkish seismic design code Turkey Although the Turkish building was revised in 1998, most of the buildings in Istanbul were constructed before 1998. $Paragraph$Since two different types of reinforcement steel were considered for each sample building, two different reinforcement-type-dependent fragility curves were obtained for each sample building in terms of each ground motion index. They are combined. Fragility parameters: Medians=[0.073, 0.701], Standard deviations=[0.016, 0.166] Syner-G taxonomy: FRM=MRF FRMM1=None FRMM2=RC-LSC NS=5 P=IR E=IR C=B CM= D=ND FS= FSM= DRS=None RSM= HL=None CL=LC Taxonomy link: https://publications.jrc.ec.europa.eu/repository/bitstream/JRC80560/lbna25883enn.pdf

Reference

SYNER-G Report: https://cordis.europa.eu/docs/results/244061/final1-syner-g-final-report.pdf. | M. S. Kirçil & Z. Polat. Fragility analysis of mid-rise R/C frame buildings. Engineering Structures, Vol 28(9),pp.1335-1345, 2006

License

This work is shared in an open access format according to the European Commission's guidelines for the FP7-ENV-2009-1 projects. See also https://cordis.europa.eu/project/id/244061/results

Exposure attributes

Primary hazard: Earthquake
Secondary hazard: --
Continent: Europe
Country: Türkiye
Region/City: --
building:Direction: --
building:Material: CR
building:LLRS: LFM
building:Height: HEX:5
building:Year: --
building:Surroundings: --
building:Occupancy: --
building:Ground floor hydrodynamics: --
building:Roof Shape: --
building:Floor material: --
building:Foundations: --
building:Fire protection: --