PRC-Geom2-NA-C
Description
RINTChttps://www.reluis.it/en/rintc-dff/ | Type of structure:Industrial Building | Construction material:Precast reinforced concrete | Rigid diaphragm:Yes | Design actions:Seismic design | AgS Tr=475yrs:0.168 | Site:Naples | Soil Class:C | N. Stories:1 | Building:Geom2 | Type of Analisys:modal response spectrum q=2.5 | Beam-column connection:dowels | Cladding:Precast cladding panels | ID building:PRC-Geom2-NA-C | Performance:GC | Curve fitting method:ML | IM:Sa(2.0s) | eta:-0.939 | beta:0.047 | Rate of failure:7.48e-06 | CoV rate:nan | LFM:0.35 | Notes:nan
Reference
Iervolino, I., Baraschino, R., Belleri, A., Cardone, D., Della Corte, G., Franchin, P., Lagomarsino, S., Magliulo, G., Marchi, A., Penna, A., Viggiani, L. R. S., & Zona, A. (2023). Seismic Fragility of Italian Code-Conforming Buildings by Multi-Stripe Dynamic Analysis of Three-Dimensional Structural Models. Journal of Earthquake Engineering, 27(15), 4415–4448. https://doi.org/10.1080/13632469.2023.2167931| Gajera, K., B. Dal Lago, L. Capacci, and F. Biondini. 2021. Multi-stripe seismic assessment of precast industrial buildings with cladding panels. Frontiers in Built Environment 7 (May):1–15. doi:https://doi.org/10.3389/fbuil.2021.631402| Magliulo, G., C. Di Salvatore, and M. Ercolino. 2021. Modeling of the beam-to-column dowel connection for a single_x0002_story RC precast building. Frontiers in Built Environment 7 (2):1–10. doi:https://doi.org/10.3389/fbuil.2021.627588| Magliulo, G., D. Bellotti, M. Cimmino, and R. Nascimbene. 2018. Modeling and seismic response analysis of RC precast Italian code-conforming buildings. Journal of Earthquake Engineering 22 (sup2):140–67. doi:10.1080/13632469.2018.1531093.| Bressanelli, ME, Bellotti, D, Belleri A, Cavalieri F, Riva P, Nascimbene R. 2021. Influence of Modelling Assumptions on the Seismic Risk of Industrial Precast Concrete Structures. Frontiers in Built Environment 7:629956. DOI: 10.3389/fbuil.2021.629956
License
This work is licensed under Creative Commons Attribution-NoDerivatives 4.0 International - https://creativecommons.org/licenses/by-nd/4.0/deed.en. See also https://www.reluis.it/en/rintc-dff/
Exposure attributes
Primary hazard: |
Earthquake |
Secondary hazard: |
-- |
Continent: |
Europe |
Country: |
Italy |
Region/City: |
Naples |
building:Direction: |
-- |
building:Material: |
CR |
building:LLRS: |
LFM |
building:Height: |
HEX:1 |
building:Year: |
YBET:2008,2018 |
building:Surroundings: |
-- |
building:Occupancy: |
IND |
building:Ground floor hydrodynamics: |
-- |
building:Roof Shape: |
-- |
building:Floor material: |
-- |
building:Foundations: |
-- |
building:Fire protection: |
-- |