E3.1

Description

High-rise power transmission power tower | Overall height 122m; nominal height 110m; distance between two feet is 20.24m; square tower's cross section, total mass is 1.3x10^5 kg; thin-walled steel tubing for horizontal members and diagonal braces; and angle steel top connecting member | Derivation method: A(A: analytical; E: empirical; O: expert opinion; H: hybrid)

Reference

Nirandjan, S., Koks, E. E., Ye, M., Pant, R., Van Ginkel, K. C. H., Aerts, J. C. J. H., and Ward, P. J.: Review article: Physical vulnerability database for critical infrastructure hazard risk assessments – a systematic review and data collection, Nat. Hazards Earth Syst. Sci., 24, 4341–4368, https://doi.org/10.5194/nhess-24-4341-2024, 2024.

License

Creative Commons Attribution 4.0 International - https://creativecommons.org/licenses/by/4.0/legalcode. See also https://zenodo.org/records/10203846

Exposure attributes

Primary hazard: Flood
Secondary hazard: --
Continent: Europe
Country: Ukraine
Region/City: --
power grid:Component: TMT
power grid:Anchorage: --
power grid:Code provisions: --